Victron MultiPlus-II 12V/4k 160-50 2x120V 50/60Hz Inverter/Charger

$1,455.00 $1,360.43 (Available - Call for Info 877-999-3699)
SALE!

Victron MultiPlus-II 12V/4k 160-50 2x120V 50/60Hz Inverter/Charger

$1,455.00 $1,360.43 (Available - Call for Info 877-999-3699)

MultiPlus-II 12V/4k 160-50 2x120V 50/60Hz Inverter/Charger

120/240 V input & output, or 120 V input and output (Always 120 V output when in inverter mode)

The AC input can be supplied from a split-phase 120/240 V source, or a... Read More...

SKU: #590731793761933 | Model: #PMP122405210

Share:

MultiPlus-II 12V/4k 160-50 2x120V 50/60Hz Inverter/Charger

120/240 V input & output, or 120 V input and output (Always 120 V output when in inverter mode)

The AC input can be supplied from a split-phase 120/240 V source, or a single-phase 120 V source. When an AC source is available, the MultiPlus will feed through the AC to its output. The output will therefore mirror the AC input. The inverter/charger connects to the neutral and the preferred input line (L1). Power needed to charge the batteries will therefore be drawn from L1. The MultiPlus switches to inverter operation when no AC source is available. The inverter output is 120 V single-phase. In inverter mode, the MultiPlus connects both output lines (L1 and L2) to provide 120 VAC to loads on either line. Any 240 V loads will therefore be supplied only when the MultiPlus is supplied by a split-phase AC source. This prevents heavy loads such as water heaters or 240 V air conditioners from discharging the battery.

PowerControl & PowerAssist - Boosting the capacity of the grid or a generator

A maximum grid or generator current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function).  PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery. When the load reduces, the spare power is used to recharge the battery (available on L1 input only).

Two AC Outputs

The main output has no break functionality. The MultiPlus takes over the supply to the connected 120 V loads in the event of a grid failure or when shore/generator power is disconnected. The transfer time of the L1 output is less than 18 milliseconds so that computers and other electronic equipment will continue to operate without disruption. The transfer time of the L2 output is longer: approximately 40 milliseconds. The second (auxiliary) output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery can be connected to this output.

Virtually unlimited power thanks to parallel and three phase operation

Up to 6 Multis can operate in parallel to achieve higher power output. In addition to parallel connection, three units of the same model can be configured for three phase output. In multi-phase setups, L2 is disabled on all units.

On-site system configuring, monitoring & control

Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface needed). Several monitoring and control options are available: Cerbo GX, Ekrano GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.

Remote configuring & monitoring

Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.

Please contact your dealer for any returns, repairs or support issues related to this product.

  • SKU: #590731793761933
  • Weight: 55.40 lbs
  • Brand: Victron Energy
  • Model: PMP122405210
  • Shipping Dimensions: 11.00" x 29.00" x 14.00"

RETURN POLICY


Last updated February 08, 2021


Thank you for your purchase. We hope you are happy with your purchase. However, if you are not completely satisfied with your purchase for any reason, you may return it to us for store credit only. Please see below for more information on our return policy.

RETURNS

All returns must be postmarked within two (2) days of the purchase date. All returned items must be in new and unused condition, with all original tags and labels attached.

RETURN PROCESS

To return an item, please email customer service at customerservice@marinemaster.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging and the return form provided, and mail your return to the following address:

marinemaster.com
Attn: Returns
RMA #
397 Union Avenue  
Laconia, NH 03246  
United States  

Please note, you will be responsible for all return shipping charges. We strongly recommend that you use a trackable method to mail your return. 

REFUNDS

After receiving your return and inspecting the condition of your item, we will process your return. Please allow at least fourteen (14) days from the receipt of your item to process your return.

EXCEPTIONS    

The following items cannot be returned:
  • special order 
  • clearance 
 
For defective or damaged products, please contact us at the customer service number below to arrange a refund or exchange. 
 
Please Note
   
  • A 30% restocking fee will be charged for all returns.
  • Sale items are FINAL SALE and cannot be returned.
  • returned items must be unopened, unused, undamaged, in original packaging

QUESTIONS

If you have any questions concerning our return policy, please contact us at:
6035564422