Victron Isolation Transformer - 2000W - 115/230 VAC

Discontinued - There may be a replacement item available, please call us 877-999-3699
SALE!

Victron Isolation Transformer - 2000W - 115/230 VAC

Discontinued - There may be a replacement item available, please call us 877-999-3699

Isolation Transformer - 2000W - 115/230 VAC

Safety and prevention of galvanic corrosion The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity... Read More...

SKU: #249511632860770 | Model: #ITR040202041

Isolation Transformer - 2000W - 115/230 VAC

Safety and prevention of galvanic corrosion The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. 

Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire on board results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. 

Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc. 

It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. 

The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply. 

The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit. 

Soft startis a standard feature of a Victron Energy isolation transformer. It will prevent the shore power fuse from blowing due to the inrush current of the transformer, which would otherwise occur

Warranty Info

WarningWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.

Please contact your dealer for any returns, repairs or support issues related to this product.

  • SKU: #249511632860770
  • Weight: 30.25 lbs
  • Brand: Victron Energy
  • Model: ITR040202041
  • Shipping Dimensions: 9.00" x 18.00" x 12.00"

RETURN POLICY


Last updated February 08, 2021


Thank you for your purchase. We hope you are happy with your purchase. However, if you are not completely satisfied with your purchase for any reason, you may return it to us for store credit only. Please see below for more information on our return policy.

RETURNS

All returns must be postmarked within two (2) days of the purchase date. All returned items must be in new and unused condition, with all original tags and labels attached.

RETURN PROCESS

To return an item, please email customer service at customerservice@marinemaster.com to obtain a Return Merchandise Authorization (RMA) number. After receiving a RMA number, place the item securely in its original packaging and the return form provided, and mail your return to the following address:

marinemaster.com
Attn: Returns
RMA #
397 Union Avenue  
Laconia, NH 03246  
United States  

Please note, you will be responsible for all return shipping charges. We strongly recommend that you use a trackable method to mail your return. 

REFUNDS

After receiving your return and inspecting the condition of your item, we will process your return. Please allow at least fourteen (14) days from the receipt of your item to process your return.

EXCEPTIONS    

The following items cannot be returned:
  • special order 
  • clearance 
 
For defective or damaged products, please contact us at the customer service number below to arrange a refund or exchange. 
 
Please Note
   
  • A 30% restocking fee will be charged for all returns.
  • Sale items are FINAL SALE and cannot be returned.
  • returned items must be unopened, unused, undamaged, in original packaging

QUESTIONS

If you have any questions concerning our return policy, please contact us at:
6035564422